Function description
The MCU TL 1gang radio 24/230 is used to control motors with max. 230 V~. It is installed near motors and switches. Integrated in boxes, it is accommodated in suspended ceilings, wiring ducts or recesses provided by the customer. The control cable is looped, i.e. run from control unit to control unit and connected to it on site. The control voltage is supplied via an upstream power supply unit.
Operation is via a central unit and/or push-buttons, whereby operation via push-buttons can be cable-connected and/or via radio. The control is carried out with time logic. This means that the system is controlled either up or down as long as a push-button is held down. If the button is held down for more than 2 seconds, the system switches to self-holding. This means that the motor runs until the limit switch is reached. If the button is pressed in the opposite direction, the motor is stopped.
If the operation is carried out via both the push-button and a central unit at the same time, the command from the central unit is superior to the push-button. If the Up and Down buttons are pressed simultaneously from different locations, the Up command has priority.